Exercício aeróbico de baixa intensidade melhora a função hemodinâmica e a mecânica respiratória em ratos com hipertensão arterial pulmonar

dc.contributor.advisorRigatto, Katya Vianna
dc.contributor.advisor-coBelló-Klein, Adriane
dc.contributor.authorBós, Denielli da Silva Gonçalves
dc.date.accessioned2016-10-13T17:53:17Z
dc.date.accessioned2023-10-09T13:59:09Z
dc.date.available2016-10-13T17:53:17Z
dc.date.available2023-10-09T13:59:09Z
dc.date.date-insert2016-10-13
dc.date.issued2013
dc.descriptionDissertação (Mestrado)-Programa de Pós-Graduação em Ciências da Saúde, Fundação Universidade Federal de Ciências da Saúde de Porto Alegre.pt_BR
dc.description.abstractO exercício aeróbico tem demonstrado benefícios em pacientes com Hipertensão Arterial Pulmonar (HAP), melhorando a dispneia e o aumento da força muscular ventilatória. Portanto, o objetivo do estudo foi avaliar o efeito de diferentes intensidades de exercício aeróbico sobre a mecânica respiratória e a função hemodinâmica em ratos com HAP. Ratos Wistar foram induzidos à HAP através de dose única de monocrotalina (50mg/kg), divididos em três grupos: HAP-sedentários (HAP-S; n=5); HAP-treinamento intensidade baixa (HAP-B; 40% da velocidade máxima teste de esforço; n=6); HAP-treinamento intensidade moderada (HAP-M; 60% da velocidade máxima teste de esforço; n=8). O protocolo de exercício aeróbico consistiu em caminhada em esteira por três semanas (5x/semana/50min). Após três semanas, foram traqueostomizados, para a análise da mecânica respiratória (FlexiVent) e cateterizados para avaliação hemodinâmica. Os dados foram comparados por ANOVA de uma via seguida pelo teste Student-Newman-Keuls (P<0,05). Os grupos submetidos ao treinamento aeróbico tiveram uma pressão ventricular sistólica direita significativamente (P<0,05) menor quando comparados aos animais sedentários (HAP-S=40±9,6; PAH-L=25±2,6; PAH-M=29±5,1; mmHg). A elastância estática foi menor no grupo HAP-B quando comparado ao HAP-M (HAP B=0,71±0,05 vs. HAP-M=0,98±0,16; cmH20/mL) e a elastância dinâmica foi menor no HAP-B quando comparado ao HAP-S (HAP-B=1,47±0,14 vs. HAP-S=1,91±0,31; cmH2O/mL). Complacência estática foi maior no grupo HAP-B (HAP-B=1,40±0,10 vs. HAP-S=1,17±0,14; mL/cmH2O) e menor no HAP-M (HAP-M=1,05±0,16 vs.HAP B=1,47±0,14; mL/cmH2O), complacência dinâmica foi maior no grupo HAP-B (HAP B=0,68±0,06 vs. HAP-S=0,53±0,09; mL/cmH2O) em relação ao HAP-M (HAP B=0,68±0,06 vs. HAP-M=0,57±0,05; mL/cmH2O). O resultado mais relevante desse estudo foi que o treinamento aeróbico diminuiu significativamente a pressão ventricular direita nos ratos com HAP, no entanto, apenas o exercício de baixa intensidade melhorou a mecânica respiratória. Coletivamente, esses resultados indicam que o exercício de baixa intensidade é eficaz para reduzir a pressão no ventrículo direito e melhorar a condição cardiorrespiratória na HAPpt_BR
dc.description.abstract-enAerobic exercise has been beneficial in patients with Pulmonary Arterial Hypertension (PAH), improving dyspnea and increasing ventilatory muscle strength. On the other hand, it is not very well known which intensity of exercise has better effects on respiratory mechanics and hemodynamic function and less risk to PAH patients. PAH was induced in Wistar rats by a single dose of monocrotaline (50mg/kg; s.c.) in three different groups: PAH-sedentary rats (PAH-S; n=5) and exercised rats in a treadmill for three weeks (5x/week/50min) at low intensity (PAH L, 40% of maximum speed in incremental test; n=6) and moderate intensity of exercise-training (PAH-M, 60% of the maximum speed in incremental test; n=8). After 3 weeks, rats were tracheostomized to study the respiratory mechanics (FlexiVent) and catheterized for hemodynamic evaluation. Data were compared by one-way ANOVA test followed by Student-Newman-Keuls test (P<0.05). Exercise in both intensities significantly decreased (P<0.05) right ventricular systolic pressure elevation induced by monocrotaline (RVSP) (PAH-S=40±9.6; PAH-L=25±2.6; PAH M=29±5.1; mmHg) compared to PAH-S. The quasi-static elastance was significantly lower in PAH-L versus PAH-M group (0.71±0.05 vs. 0.98±0.16; cmH2O/mL), whereas the respiratory elastance was lower in the PAH-L versus PAH-S group (1.47±0.14 vs. 1.91±0.31; cmH2O/mL). Quasi-static compliance was significantly higher in PAH-L versus PAH-S (1.40±0.10 vs. 1.17±0.14; mL/cmH2O) and lower in PAH-M versus PAH-L (1.05±0.16 vs. 1.47±0.14; mL/cmH2O). The respiratory system compliance was higher in PAH-L either when compared to the sedentary and moderate groups (PAH-L=0.68±0.06 vs. PAH-S=0.53±0.09, and vs. PAH-M=0.57±0.05; mL/cmH2O, P<0.05). Collectively, these results indicate that low intensity of an aerobic exercise is effective to decrease the RVSP, which results in a better cardiorespiratory condition during PAH.pt_BR
dc.identifier.urihttps://repositorio.ufcspa.edu.br/handle/123456789/255
dc.language.isopt_BRpt_BR
dc.relation.requiresAdobe Readerpt_BR
dc.rightsAcesso Aberto Imediato*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectHipertensão Pulmonarpt_BR
dc.subjectMonocrotalinapt_BR
dc.subjectExercíciopt_BR
dc.subjectMecânica Respiratóriapt_BR
dc.subject[en] Hypertension, Pulmonaryen
dc.subject[en] Monocrotalineen
dc.subject[en] Exerciseen
dc.subject[en] Respiratory Mechanicsen
dc.titleExercício aeróbico de baixa intensidade melhora a função hemodinâmica e a mecânica respiratória em ratos com hipertensão arterial pulmonarpt_BR
dc.typeDissertaçãopt_BR
Arquivos
Pacote Original
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
[DISSERTAÇÃO] Bós, Denielli da Silva Gonçalves.pdf
Tamanho:
2.44 MB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Plain Text
Descrição: