Avaliação dos resultados cirúrgicos de implantes do sistema Baha Attract comparando a incisão em forma de C e a técnica de incisão linear
dc.contributor.advisor | Lubianca Neto, José Faibes | pt_BR |
dc.contributor.advisor-co | Miura, Mauricio | pt_BR |
dc.contributor.author | Ogando, Patrícia Barcelos | pt_BR |
dc.contributor.department | Programa de Pós-Graduação em Pediatria: Atenção à Saúde da Criança e ao Adolescente | pt_BR |
dc.date.accessioned | 2025-06-09T19:28:07Z | |
dc.date.available | 2025-06-09T19:28:07Z | |
dc.date.date-insert | 2025-06-09 | |
dc.date.issued | 2023-11-18 | |
dc.description | Dissertação (Mestrado) - Programa de Pós-Graduação em Pediatria, Fundação Universidade Federal de Ciências da Saúde de Porto Alegre. | pt_BR |
dc.description.abstract | Introdução: A audição é o sentido que nos permite perceber os sons ao nosso redor e nos comunicar. A perda auditiva, por sua vez, leva à redução na qualidade de vida e a menores níveis sociais e educacionais. Na infância, a perda auditiva é um problema silencioso com repercussões graves no desenvolvimento da linguagem, cognitivo e educacional. O tratamento da perda auditiva deve ser individualizado de acordo com o grau e tipo de perda. As próteses auditivas de condução óssea (PAAO) são uma família de soluções auditivas em que o som é transmitido por vibração através da calota craniana diretamente para a cóclea, sendo indicados nos casos de PA condutiva, mista ou surdez unilateral. BAHA® Attract é uma PAAO percutânea disponível desde 2013. A técnica cirúrgica preconizada consiste na realização de uma incisão semicircular (em forma de C). Porém, com o objetivo de reduzir o tempo cirúrgico e o índice de reação cutânea, foi proposta uma incisão linear sobre o local do implante. Até o momento, nenhum trabalho havia comparado a técnica convencional com a incisão linear para implante do Baha® Attract. Objetivos: O objetivo deste estudo é comparar o tempo operatório e a incidência das complicações pós-operatórias usando duas técnicas diferentes para o implante do sistema Baha® Attract: a técnica convencional de incisão em C e a técnica de incisão linear, tanto em adultos quanto em crianças. Metodologia: Trata-se de um estudo de coorte retrospectivo, com pacientes submetidos ao implante do sistema Baha® Attract durante um período de 4 anos (2015-2019). Foram analisados dados epidemiológicos como gênero e idade, doença otológica, tipo de perda auditiva, técnica cirúrgica, tempo operatório, taxa de infecção e procedimentos subsequentes. Resultados: Foram incluídos 38 pacientes. As cirurgias foram realizadas sob anestesia geral. O tempo cirúrgico foi significativamente menor nos pacientes submetidos à técnica linear quando comparados com a técnica em C (76,55 minutos, DP±16,75 vs. 93,17 minutos, DP±19,82, respectivamente; p=0,007). Não houve diferença no índice de complicações pós-operatórias entre os grupos. Conclusões: Conclui-se que a técnica linear para implante de BAHA Attract é associada a um menor tempo cirúrgico em relação à técnica em C, sem aumento do número de complicações pós-operatórias. | pt_BR |
dc.description.abstract-en | Introduction: Hearing is the sense that allows us to perceive the sounds around us and communicate. Hearing loss (HL) leads to a reduction in quality of life and lower social and educational levels. In childhood, HL is a silent problem with serious repercussions on language, cognitive and educational development. HL treatment should be individualized according to the degree and type of loss. Bone conduction hearing aids are a family of hearing solutions in which sound is transmitted by vibration through the skull directly to the cochlea, being indicated in cases of conductive, mixed or unilateral deafness. The BAHA® Attract is a percutaneous bone anchored hearing implant available since 2013. The recommended surgical technique consists of a semicircular incision (C-shaped incision); however, previous reports described a simplified linear incision with shorter operative time and reduced soft tissue reaction. Until now, no previous reports had compared the conventional technique with the linear incision for implantation of the Baha® Attract. Objectives: The aim of this study is to compare the operative time and postoperative complication outcomes using two different techniques for the implantation of the Baha® Attract system: the conventional C-shaped incision technique and the linear incision technique, both in adults and in children. Methodology: This is a retrospective cohort study, of patients who underwent implantation of the Baha® Attract system over a period of 4 years (2015-2019). Epidemiological data such as gender and age, otological disease, type of hearing loss, surgical technique, operative time, infection rate and subsequent procedures were analyzed. Results: A total of 38 patients were included. The implantation was carried out under general anesthesia. Operative time was significant lower with the linear technique compared to the C-shaped technique (76.55 minutes, SD 16.75 vs. 93.17 minutes, SD 19.82; p=0.007). There was no difference in postoperative complications between the two techniques. Conclusions: The use of linear incision for transcutaneous BAHA® system implantation is associated with a reduced surgery time compared to the C-shaped technique, with no increase in postoperative complications. | en |
dc.identifier.uri | https://repositorio.ufcspa.edu.br/handle/123456789/3312 | |
dc.language.iso | pt_BR | pt_BR |
dc.relation.requires | TEXTO - Adobe Reader | pt_BR |
dc.rights | Acesso Aberto Imediato | pt_BR |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/br/ | |
dc.subject | Auxiliares de Audição | pt_BR |
dc.subject | Perda Auditiva | pt_BR |
dc.subject | Complicações Pós-Operatórias | pt_BR |
dc.subject | [en] Baha Attract | en |
dc.subject | [en] Hearing Aids | en |
dc.subject | [en] Hearing Loss | en |
dc.subject | [en] Postoperative Complications | en |
dc.title | Avaliação dos resultados cirúrgicos de implantes do sistema Baha Attract comparando a incisão em forma de C e a técnica de incisão linear | pt_BR |
dc.type | Dissertação | pt_BR |
Arquivos
Pacote Original
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- [DISSERTAÇÃO] Ogando, Patrícia Barcelos (C).pdf
- Tamanho:
- 13.32 MB
- Formato:
- Adobe Portable Document Format
- Descrição:
- Texto Completo