Avaliação da qualidade do ar em sala de emergência pediátrica em um hospital de Porto Alegre – RS

dc.contributor.advisorAmantéa, Sérgio Luispt_BR
dc.contributor.advisor-coRhoden, Cláudia Ramospt_BR
dc.contributor.authorCabral, Catiane Zanin
dc.date.accessioned2016-07-07T18:12:46Z
dc.date.accessioned2023-10-09T13:59:07Z
dc.date.available2016-07-07T18:12:46Z
dc.date.available2023-10-09T13:59:07Z
dc.date.date-insert2016-07-07
dc.date.issued2015
dc.descriptionDissertação (Mestrado)-Programa de Pós-Graduação em Ciências da Saúde, Fundação Universidade Federal de Ciências da Saúde de Porto Alegre.pt_BR
dc.description.abstractO presente artigo retrata um estudo, realizado no Serviço de Pediatria de um hospital infantil do Rio Grande do Sul – Brasil, que visou a determinar a concentração dos poluentes atmosféricos NO2 e MP2,5, amostrados do ambiente de uma sala de espera de serviço de emergência pediátrica, e a relação com a população presente nestes locais. As concentrações de NO2 e MP2,5 foram aferidas através de monitoramento passivo e monitoramento ativo, respectivamente, durante as quatro estações do ano. Foi verificado um aumento significativo na concentração do MP2,5 no outono, quando comparado com as outras estações (P<0,001). O aumento deste poluente, nesta estação, foi acompanhado pelo incremento do número de pessoas na emergência hospitalar (P=0,026). O comportamento simétrico entre MP2,5 e número de pessoas é ratificado pela correlação positiva entre estas duas variáveis (r=738; P<0,001). Além disso, o NO2, no outono, apresentou concentração estatisticamente maior do que as concentrações registradas nas outras estações do ano (P=0,014). Em conclusão a correlação encontrada entre o número de pessoas e as concentrações de MP2,5 durante todo o período de amostragem demonstra a relação entre a poluição indoor em um ambiente hospitalar e o grau de lotação de tal local.pt_BR
dc.description.abstract-enThis article shows a study conducted at the Department of Pediatrics of a children's hospital in Rio Grande do Sul - Brazil and aimed to determine the concentration of air pollutants NO2 and PM2.5 sampled from a waiting room of a pediatric emergency department environment and this relationship with these local population. Concentrations of NO2 and PM2.5 were measured through passive monitoring and active monitoring, respectively, during the four seasons. A significant increase in the concentration of PM2.5 fall was observed when compared to the other seasons (P <0.001). The increase of this pollutant, this season, was accompanied by an increase in the number of people in hospital emergency (P = 0.026). The symmetrical behavior between PM2.5 and number of people is ratified by the positive correlation between these two variables (r = 738, P <0.001). In addition, NO2, in the fall, had statistically significant higher than concentrations recorded in other seasons concentrations (P = 0.014). In conclusion, the fall was the season which were measured higher concentrations of NO2 and PM2.5, this increase was accompanied by the number of individuals present in the pediatric emergency service. The correlation found between the number of people and PM2.5 concentrations throughout the sampling period demonstrates the relationship between indoor pollution in a hospital setting and the degree of capacity of such a site.en
dc.identifier.urihttps://repositorio.ufcspa.edu.br/handle/123456789/154
dc.language.isootherpt_BR
dc.relation.requiresAdobe Readerpt_BR
dc.rightsAcesso Aberto Imediato*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectPoluição do Arpt_BR
dc.subjectEmergênciaspt_BR
dc.subjectPediatriapt_BR
dc.subjectMaterial Particuladopt_BR
dc.subjectDióxido de Nitrogênioen
dc.subject[en] Air Pollutionen
dc.subject[en] Emergenciesen
dc.subject[en] Pediatricsen
dc.subject[en] Particulate Matteren
dc.subject[en] Nitrogen Dioxideen
dc.titleAvaliação da qualidade do ar em sala de emergência pediátrica em um hospital de Porto Alegre – RSpt_BR
dc.typeDissertaçãopt_BR
Arquivos
Pacote Original
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
[DISSERTAÇÃO] Cabral, Catiane Zanin.pdf
Tamanho:
9.15 MB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Plain Text
Descrição: