Field Hip Stability Isometric Test (F-HipSIT): Reliability of a posterolateral hip musculature strength assessment in the sport setting

dc.contributor.advisorBaroni, Bruno Manfredinipt_BR
dc.contributor.advisor-coAlvares, João Breno de Araujo Ribeiropt_BR
dc.contributor.authorSilva, Felipe Xavier de Lima ept_BR
dc.contributor.departmentPrograma de Pós-Graduação em Ciências da Reabilitaçãopt_BR
dc.date.accessioned2024-12-05T12:21:24Z
dc.date.available2024-12-05T12:21:24Z
dc.date.date-insert2024-12-05
dc.date.issued2021-12-21
dc.descriptionDissertação (Mestrado) - Programa de Pós-Graduação em Ciências da Reabilitação, Fundação Universidade Federal de Ciências da Saúde de Porto Alegre.pt_BR
dc.description.abstractIntrodução: A musculatura posterolateral do quadril tem importante papel na prevenção e reabilitação de lesões esportivas. O Hip Stability Isometric Test (HipSIT) é um teste confiável usado para avaliar a força da musculatura posterolateral do quadril no ambiente clínico. No entanto, a necessidade de uma maca e o tempo gasto para ajustar o cinto fixador do dinamômetro manual (HDD) podem ser uma barreira para a implementação do HipSIT no cenário esportivo, principalmente em esportes coletivos. Objetivo: Verificar a confiabilidade intra-avaliadores e interavaliadores de uma avaliação de força da musculatura posterolateral do quadril aplicada à equipes esportivas em suas instalações. Chamamos este teste de Campo HipSIT (F-HipSIT). Métodos: Dois avaliadores independentes (denominados “Avaliador A” e “Avaliador B”) participaram de duas sessões de testes nas instalações de treinamento das equipes (denominadas “Dia 1” e “Dia 2”) intercaladas por pelo menos uma semana. Sessenta atletas amadores (30 homens e 30 mulheres) foram avaliados por meio do F-HipSIT. A ordem dos avaliadores em cada sessão de teste, bem como a ordem dos participantes e seus lados a serem testados, foram previamente randomizados. Coeficiente de correlação intraclasse (ICC), erro padrão de medida (SEM), coeficiente de variação (CV) e mudança mínima detectável (MDC) foram analisados. Resultados: O avaliador A obteve valores de força de 0,41±0,07 kgf/kg e 0,42±0,07 kgf/kg no “Dia 1” e no “Dia 2”, respectivamente. O avaliador B obteve 0,38±0,07 kgf/kg e 0,40 ±0,08 kgf/kg nas duas sessões de teste. O F-HipSIT apresentou boa confiabilidade interavaliadores (ICCs de 0,78-0,85), com SEM de 0,03 kgf/kg, MDC de 0,05-0,06 kgf/kg e CV de 7,1-8,6%. Ao mesmo tempo, o F-HipSIT mostrou boa confiabilidade intra-avaliador (ICCs de 0,88-0,89), com SEM de 0,02 kgf/kg, MDC de 0,03 kgf/kg e CV de 5,9-6,3%. Conclusão: O F-HipSIT apresentou boa confiabilidade intra e interavaliadores. As equipes médica/treinadora de esportes coletivos podem incluir o F-HipSIT na rotina de avaliações para monitorar a força muscular posterolateral do quadril de atletas competitivos rapidamente em qualquer lugar.pt_BR
dc.description.abstract-enIntroduction: The posterolateral hip musculature plays a role on prevention and rehabilitation of sports injuries. The Hip Stability Isometric Test (HipSIT) is a reliable protocol used to assess the posterolateral hip musculature strength in the clinical setting. However, the need for a stretcher and the time spent to adjust the strap into which the hand-held dynamometer (HDD) must be properly fitted may be a barrier for implementing the HipSIT in the sports setting, especially in team sports. Objective: To verify the intra-rater and inter-rater reliability of a posterolateral hip musculature strength assessment applied to the athletic population at their sports facilities. We named this test Field HipSIT (F-HipSIT). Methods: Two independent raters (named “Rater A” and “Rater B”) attended training facilities in two sessions (named “Day 1” and “Day 2”) interspaced by at least one week. Sixty amateur athletes (30 male and 30 female) were assessed using the F-HipSIT. The order of raters in each testing session, as well as the order of participants and their sides to be tested, were previously randomized. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), coefficient of variation (CV), and minimal detectable change (MDC) were analyzed. Results: Rater A obtained strength values of 0.41±0.07 kgf/kg and 0.42±0.07 kgf/kg in “Day 1” in “Day 2”, respectively. Rater B obtained 0.38±0.07 kgf/kg and 0.40±0.08 kgf/kg in the two testing sessions. The F-HipSIT presented good inter-rater reliability (ICCs of 0.78-0.85), with an SEM of 0.03 kgf/kg, an MDC of 0.05-0.06 kgf/kg and a CV of 7.1-8.6%. Concurrently, the F-HipSIT showed good intra-rater reliability (ICCs of 0.88-0.89), with an SEM of 0.02 kgf/kg, an MDC of 0.03 kgf/kg and a CV of 5.9-6.3%. Conclusion: The F-HipSIT presented good intra- and inter-rater reliability. The medical/coaching staff of team sports can include the F-HipSIT in the screening routine for monitoring the posterolateral hip muscle strength of competitive athletes quickly anywhere.en
dc.identifier.urihttps://repositorio.ufcspa.edu.br/handle/123456789/3085
dc.language.isopt_BR
dc.relation.requiresTEXTO - Adobe Readerpt_BR
dc.rightsAcesso Aberto Imediatopt_BR
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/br/
dc.subjectForça muscularpt_BR
dc.subjectQuadrilpt_BR
dc.subjectDinamômetro de Força Muscularpt_BR
dc.subjectLesão esportivapt_BR
dc.subject[en] Muscle Strengthen
dc.subject[en] Hipen
dc.subject[en] Muscle Strength Dynamometeren
dc.subject[en] Sport injuryen
dc.titleField Hip Stability Isometric Test (F-HipSIT): Reliability of a posterolateral hip musculature strength assessment in the sport settingen
dc.typeDissertaçãopt_BR
Arquivos
Pacote Original
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
[DISSERTAÇÃO] Silva, Felipe Xavier de Lima e (C).pdf
Tamanho:
1.8 MB
Formato:
Adobe Portable Document Format
Descrição:
Texto completo